Zephyr Non-Isolated SMT DC-DC Power Module:

0.8V to 3.5V @ 20A Output, 5V to 12V Input

LINEAGE

POWER

25

Data Sheet
March 31, 2010

Fusing Considerations


A 10A fuse is required for input voltages of 10.6V and higher. It is not required for input voltages below
10.6V. The following fuse or equivalent is recommended:

Characteristic

Fuse Parameter

Littlefuse R451010 Nano

2

SMF

Fuse Current Rating

10A

10A

Voltage Rating

32 minimum

125

I

2

t 100

a

2

sec maximum

26.4 a

2

sec

DC Interruption Rating

(must be DC rated, not just

AC rated)

35A minimum

35A

UL Recognized

Mandatory

Yes


The fuse should be located in the input voltage bus side of the input capacitor to minimize inductance
between the input capacitor and the Zephyr Power Module. The fuse should not be located in proximity to
any object which might abnormally ‘preheat’ the fuse, causing undesired melting.

The Zephyr Power Module begins regulating with an input voltage above approximately 4V and will draw
more input current at lower voltages. If the input voltage rise times and fall times are too slow, shorter fuse
life and nuisance opening may occur. To minimize such fuse input current stresses, the module should be
enabled after input voltage is applied and disabled before input voltage is removed, by using the OUTEN pin.

Fuse, 10A

Minimize this

distance and

inductance



Input

Capacitor

V

IN

-

V

IN

+

Zephyr Module




DC
Input
Bus

To other
modules

or circuits

OUTEN

Figure 47. Fuse Placement

Advertising