Safety considerations, Feature descriptions – GE Industrial Solutions Zephyr Non-Isolated SMT User Manual

Page 6

Advertising
background image

Zephyr Non-Isolated SMT DC-DC Power Module:
0.8V to 3.5V @ 20A Output, 5V to 12V Input

LINEAGE

POWER

6

Data Sheet

March 31, 2010

Safety Considerations

Module’s printed circuit board meets the standards of UL flammability specifications per UL94V-0.

Feature Descriptions

Static Voltage Regulation

The output voltage measured at the converter output pins on the system board will be within the range
shown in Table 3, except during turn-on and turn-off periods. The static limits apply to ambient temperatures
between 0

°C and 70 °C. Static voltage regulation includes:

• DC output initial voltage and set point adjust

• Output load ranges specified in tables above

• Temperature and warm-up input voltage tolerances specified in input voltage and current

Turn-on Response Time

The output voltage will be within the specified range within 10 ms of the input voltage reaching 90% of its
nominal value with O

UTEN

present. When O

UTEN

is applied with input voltage present, the output voltage will

be inside its specified range within 10 ms. Figure 1 and Figure 2 represent typical start-up waveforms with
the maximum load current and load capacitor on the output indicated in Table 3. A pull-up resistor of 10 k

Ω

is used between Module OK pin and 5V.

O

UTEN

, 5 V/div

O

UTEN

, 5 V/div

M

ODULE

OK, 5 V/div

M

ODULE

OK, 5 V/div

V

OUT

, 1.0 V/div

V

OUT

, 0.5 V/div

2 ms/div

2 ms/div


Figure 1. Turn-on Waveform: V

IN

= 12V,

Figure 2. Turn-on Waveform: V

IN

= 5V,

V

OUT

= 0.8V, 16A resistive load + 10,000

μF

V

OUT

= 3.3V, 16A resistive load + 1,000

μF

Advertising