12a digital slimlynx, Open frame: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Digital SlimLynx Open Frame User Manual

Page 13: Design considerations, Safety considerations

Advertising
background image

GE

Data Sheet

12A Digital SlimLynx

TM

Open Frame: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Corporation. All rights reserved.

Page 13


Design Considerations

Input Filtering

The 12A Digital SlimLynx

TM

Open Frame module should be

connected to a low ac-impedance source. A highly
inductive source can affect the stability of the module. An
input capacitance must be placed directly adjacent to the

input pin of the module, to minimize input ripple voltage
and ensure module stability.
To minimize input voltage ripple, ceramic capacitors are

recommended at the input of the module. Figure 37 shows
the input ripple voltage for various output voltages at 12A

of load current with 1x22 µF or 2x22 µF ceramic
capacitors and an input of 12V.

Figure 37. Input ripple voltage for various output
voltages with 2x22 µF or 3x22 µF ceramic capacitors at

the input (12A load). Input voltage is 12V.

Output Filtering

These modules are designed for low output ripple voltage
and will meet the maximum output ripple specification with
3x0.047 µF ceramic and 2x47 µF ceramic capacitors at the

output of the module. However, additional output filtering
may be required by the system designer for a number of
reasons. First, there may be a need to further reduce the
output ripple and noise of the module. Second, the dynamic
response characteristics may need to be customized to a
particular load step change.

To reduce the output ripple and improve the dynamic
response to a step load change, additional capacitance at
the output can be used. Low ESR polymer and ceramic
capacitors are recommended to improve the dynamic
response of the module. Figure 38 provides output ripple
information, measured with a scope with its Bandwidth
limited to 20MHz for different external capacitance values at
various Vo and a full load current of 12A. For stable
operation of the module, limit the capacitance to less than
the maximum output capacitance as specified in the
electrical specification table. Optimal performance of the
module can be achieved by using the Tunable Loop

TM

feature

described later in this data sheet.

Figure 38. Output ripple voltage for various output
voltages with external 2x47 µF, 4x47 µF, 6x47 µF or 8x47

µF ceramic capacitors at the output (12A load). Input
voltage is 12V.

Safety Considerations

For safety agency approval the power module must be

installed in compliance with the spacing and separation
requirements of the end-use safety agency standards, i.e.,
UL 60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 60950-

1:2006 + A11 (VDE0805 Teil 1 + A11):2009-11; EN 60950-
1:2006 + A11:2009-03.

For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the input
must meet SELV requirements. The power module has

extra-low voltage (ELV) outputs when all inputs are ELV.
The input to these units is to be provided with a fast acting
fuse (e.g. ABC Bussmann) with a maximum rating of 20 A in
the positive input lead

.




0

50

100

150

200

250

300

350

400

450

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

1x22uF

2x22 uF

0

10

20

30

40

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

R

ipple

(m

V

p

-p)

Output Voltage(Volts)

2x47uF Ext Cap
4x47uF Ext Cap
6x47uF Ext Cap
8x47uF Ext Cap

Advertising