12a digital slimlynx, Open frame: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Digital SlimLynx Open Frame User Manual

Page 28

Advertising
background image

GE

Data Sheet

12A Digital SlimLynx

TM

Open Frame: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Corporation. All rights reserved.

Page 28


Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

41 VOUT_OV_FAULT_RESPONSE

Instructs the module on what action to take in response to an output overvoltage

fault. The options are: RSP[1:0]

00 - Module continues without interruption
01 Module continue s operation for 4 switching cycles and shuts down if

fault persists

01- Module shuts down and responds to RS[2:0]
11 – Module shuts down and attempts to restart


RS[2:0]
000 – Module does not attempt to restart

111- Module goes through normal startup continuously

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r

r r

Function

RSP

[1]

RSP

[0]

RS[2] RS[1] RS[0]

X X X

Default Value

1 1 1 1 1 1 0 0

YES

44 VOUT_UV_FAULT_LIMIT

Sets the voltage level for an output undervoltage fault. Exponent is fixed at -10.

Four fixed percentages of 92%, 90%, 88%and 85% are available.

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 1 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

1 0 0 0 1 1 1 1

YES

45 VOUT_UV_FAULT_RESPONSE

Instructs the module on what action to take in response to a output
undervoltage fault.
The options are: RSP[1:0]

02 - Module continues without interruption
03 Module continue s operation for 4 switching cycles and shuts down if

fault persists

02- Module shuts down and responds to RS[2:0]

11 – Module shuts down and attempts to restart


RS[2:0]
000 – Module does not attempt to restart
111- Module goes through normal startup continuously.

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r

r r

Function

RSP

[1]

RSP

[0]

RS[2] RS[1] RS[0]

X X X

Default Value

0 0 0 0 0 1 0 0

YES

46 IOUT_OC_FAULT_LIMIT

Sets the output overcurrent fault level in A (cannot be changed)

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 1 1 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 1 1 1 1 1

YES