Data Sheet

12A Digital SlimLynx

TM

Open Frame: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

February 19, 2014

©2014 General Electric Corporation. All rights reserved.

Page 20


PU: Sets the default to either operate any time input power is
present or for the ON/OFF to be controlled by the analog

ON/OFF input and the PMBus OPERATION command. This bit
is used together with the CP, CMD and ON bits to determine
startup.

Bit Value

Action

0

Module powers up any time power is

present regardless of state of the analog
ON/OFF pin

1

Module does not power up until
commanded by the analog ON/OFF pin and

the OPERATION command as programmed
in bits [2:0] of the ON_OFF_CONFIG register.

CMD: The CMD bit controls how the device responds to the
OPERATION command.

Bit Value

Action

0

Module ignores the ON bit in the OPERATION
command

1

Module responds to the ON bit in the

OPERATION command

CPR: Sets the response of the analog ON/OFF pin. This bit is
used together with the CMD, PU and ON bits to determine

startup.

Bit Value

Action

0

Module ignores the analog ON/OFF pin, i.e.

ON/OFF is only controlled through the
PMBUS via the OPERATION command

1

Module requires the analog ON/OFF pin to
be asserted to start the unit

PMBus Adjustable Soft Start Rise Time

The soft start rise time can be adjusted in the module via
PMBus. When setting this parameter, make sure that the
charging current for output capacitors can be delivered by
the module in addition to any load current to avoid nuisance
tripping of the overcurrent protection circuitry during
startup. The TON_RISE command sets the rise time in ms,
and allows choosing soft start times between 600μs and

9ms, with possible values listed in Table 5. Note that the
exponent is fixed at -4 (decimal) and the upper two bits of
the mantissa are also fixed at 0.

Table 5

Rise Time

Exponent

Mantissa

600μs 11100 00000001010
900μs 11100 00000001110
1.2ms 11100 00000010011
1.8ms 11100 00000011101
2.7ms 11100 00000101011
4.2ms 11100 00001000011
6.0ms 11100 00001100000
9.0ms 11100 00010010000

Output Voltage Adjustment Using the PMBus

The VOUT_SCALE_LOOP parameter is important for a
number of PMBus commands related to output voltage
trimming, margining, over/under voltage protection and the
PGOOD thresholds. The output voltage of the module is set
as the combination of the voltage divider formed by RTrim
and a 20kΩ upper divider resistor inside the module, and the

internal reference voltage of the module. The reference
voltage V

REF

is nominally set at 600mV, and the output

regulation voltage is then given by

REF

OUT

V

RTrim

RTrim

V

×





+

=

20000

Hence the module output voltage is dependent on the value

of RTrim which is connected external to the module. The
information on the output voltage divider ratio is conveyed
to the module through the VOUT_SCALE_LOOP parameter

which is calculated as follows:

RTrim

RTrim

LOOP

SCALE

VOUT

+

=

20000

_

_

The VOUT_SCALE_LOOP parameter is specified using the

“Linear” format and two bytes. The upper five bits [7:3] of the
high byte are used to set the exponent which is fixed at –9
(decimal). The remaining three bits of the high byte [2:0] and
the eight bits of the lower byte are used for the mantissa.
The default value of the mantissa is 00100000000

corresponding to 256 (decimal), corresponding to a divider
ratio of 0.5. The maximum value of the mantissa is 512
corresponding to a divider ratio of 1. Note that the

resolution of the VOUT_SCALE_LOOP command is 0.2%.

When PMBus commands are used to trim or margin the
output voltage, the value of V

REF

is what is changed inside

the module, which in turn changes the regulated output
voltage of the module.

The nominal output voltage of the module can be adjusted

with a minimum step size of 0.4% over a ±25% range from
nominal using the VOUT_TRIM command over the PMBus.

The VOUT_TRIM command is used to apply a fixed offset

voltage to the output voltage command value using the