G-ænial Anterior & Posterior Technical Manual

6.7 Depth of cure

the depth of cure of G-ænial was determined with a scraping technique described in the iSO
4049:2000 specifications.

table 5: G-ænial anterior: irradiation time and effective depth of cure

irradiation time

Plasma arc (2000 mW/cm²)

Gc G-light (1200 mW/cm²)

halogen / leD (700 mW/cm²)

Shade

3 sec.
10 sec.
20 sec.

6 sec.
20 sec.
40 sec.

te, ie, Je, Se, cVe

3.0 mm

3.5 mm

a1, a2, B1, B2, XBW, BW, ae

2.5 mm

3.0 mm

a3, B3

2.0 mm

3.0 mm

a3.5, a4, c3, aO2, aO3, aO4, cV, cVD

1.5 mm

2.5 mm

table 6: G-ænial Posterior: irradiation time and effective depth of cure

irradiation time

Plasma arc (2000 mW/cm²)

Gc G-light (1200 mW/cm²)

halogen / leD (700 mW/cm²)

Shade

3 sec.
10 sec.
20 sec.

6 sec.
20 sec.
40 sec.

P-a1, P-a2, P-Je, P-ie

2.5 mm

3.0 mm

P-a3, P-a3.5

2.0 mm

3.0 mm