Installing and removing the power supply – Acer AR360 F1 User Manual

Page 57

Advertising
background image

41

Installing and removing the power

supply

The server has a single 700-Watt power supply, capable of operating at
100 - 240 input volts.

WARNING! To reduce the risk of personal injury or
damage to the equipment, the installation of power
supply modules should be referred to individuals who
are qualified to service server systems and are trained
to deal with equipment capable of generating
hazardous energy levels.

WARNING! To reduce the risk of personal injury from
hot surfaces, observe the thermal labels on each power
supply module. You can also consider wearing
protective gloves.

WARNING! To reduce the risk of personal injury from
electric shock hazards, do not open the power supply
modules. There are no serviceable parts inside the
module.

Caution! Electrostatic discharge can damage electronic
components. Make sure that you are properly
grounded before handling a power supply module.

Caution! Due to chassis airflow disruption, a power
supply bay should never be vacant for more than two
minutes when the server is powered on. Exceeding five
minutes might cause the system to exceed the
maximum acceptable temperature and possibly
damage the system components.

Caution! The power supply is only hot-pluggable if you
have a redundant system with two power supplies
installed. If you only have one power supply installed,
before removing or replacing the power supply, you
must first take the server out of service, turn off all
peripheral devices connected to the system, turn off
the system by pressing the power button, and unplug
the AC power cord from the system or wall outlet.

Advertising