H-5223 – Xylem H-5223 User Manual

Page 100

Advertising
background image

Example:

-> GOESRRRATE?

5

Command sent to the XL™.

GOES RR Rate = 00:00:30

rs

Response sent to the host system.

Command:

GOESRRRATE=hh:mm:ss

Description:

Set the transmission rate for the random report mode of the GOES radio.

Parameters:

The new rate is to be entered in the format of HH:MM:SS, where H is hours, M is
minutes, and S is seconds.

Response:

None.

Example:

-> GOESRRRATE=00:01:00

5

Command sent to the XL™.

rs

Response sent to the host system.

Command:

GOESRRTRIGGERMODE?

Description:

Read the current mode of random report operation of the GOES radio. This value,
along with trigger source, determines what conditions are checked when evaluating
whether or not to generate a GOES random report.

Parameters:

None.

Response:

An ASCII text string is returned. The response will be “Always ”, “> Set Pt”, “<
Set Pt”, or “Delta “. (See GOES section for details)

Example:

-> GOESRRTRIGGERMODE?

5

Command sent to XL™.

GOES RR Trigger Mode = Always

rs

Response from XL™.

Command:

GOESRRTRIGGERMODE=XXXXXX

Description:

Set the current mode of GOES radio random report operation.

Parameters:

The flag can be set to “Always ”, “> Set Pt”, “< Set Pt”, or “Delta “.

Response:

None.

Example:

-> GOESRRTRIGGERMODE=> Set Pt

5

Command sent to
XL™.

rs

Response from XL™.

H-5223

Remote Operation (Command Mode) C-41

Advertising