and is then used to update the real time clock.

Parameters:This command expects an input of the format mm/dd/yy, where m is the month, d m
is the day, and y is the year.

Response:

None, use the DATE? command to see the new value.

Example:

-> DATE=03/21/06

5

Command sent to the XL™.
This sets the current date to March 21st, 2006.

Command:

SITEID?

Description:

Read the Site ID. The Site ID is the text description of the site. It is 8 characters
in length.

Parameters:

None.

Response:

An ASCII text string is returned with the Site ID formatted as XXXXXXXX. The
response is terminated using a carriage return, line feed.

Example:

-> SITEID?

5

Command sent to the XL™.

SiteID = RIVER1

rs

Response sent to the host system.

Command:

SITEID=XXXXXXXX

Description:

Set the site ID. The Site ID is the text description of the site. It is 8 characters in
length.

Parameters:

The site ID gets assigned to the entered text. If the text is shorter than 8
characters, the site ID will be padded with spaces.

Response:

None, use the SITEID? command to see the new value.

Example:

-> SITEID=Site-15

5 Command sent to the XL™.

This sets the site ID to “Site-15 ".

Command: