2.0 Specifications

Maximum Working Pressure

100 psig / 6.9 bar (most models)

o o

Maximum Fluid Temperature

130 F / 54 C

o o

Ambient Temperature Range

14 to 110 F / -10 to 43 C

Duty Cycle

Continuous

Maximum Solids

50% by volume

Maximum Viscosity

5,000 Centipoise

Maximum Suction Lift

up to 30 ft. water

Power Requirements

115V60Hz 80 Watts,
220V50Hz 40 Watts,
230V60Hz 45 Watts

Dimensions

6-1/8” H x 10-1/8” W x 9” D

Weight

8 lb.

4.0 Unpacking

Your pump package should contain the following:
1 - Injector pump with 2 pump tube assemblies
1 - suction tube strainer
1 - ceramic tubing weight
1 - 5’ Length of clear PVC suction tubing
1 - 5’ Length of opaque LLDPE discharge tubing
1 - Injection fitting with internal back-flow check valve
1 - Mounting hardware kit
1 - Shroud (weather proof cover see page 10)

3.0 Features

!

Peristaltic Pump Tube does not require valves.

!

Self priming. Cannot vapor lock.

!

High outlet pressure capability of 100 psig.*

!

High inlet suction lift capability of 30 feet.

!

Patented Tube Failure Detection (TFD)system.

!

Patented pump tube assembly design.

!

Digital electronic feed rate control.

!

Pump Tube service warning timer.

!

Corrosion proof Valox housing.

!

Tamper resistant electronic control panel cover.

A-100NE

Page 3

1.0 Introduction

Thank you for purchasing the A-100N Model E Peristaltic Metering Pump.
The A-100N is designed to inject chemicals into piping systems. The pump
has been tested by NSF International for use with 12 ½% Sodium
Hypochlorite. The Model E is equipped with external input control circuitry
which allows the pumps output to be externally controlled by either a 4-
20mA input signal, a 0-10V DC input signal or a pulsed input signal.

Advertising