Rear panel controls, 7 crosspoint 42 hva matrix switcher • operation – Extron Electronics CrossPoint 42 HVA User Manual

Page 23

Advertising
background image

3-7

CrossPoint 42 HVA Matrix Switcher • Operation

V

R

G

B

H

V

INPUTS

R

3

4

2

H V H V

1

ON

2

3 4

H V H V

1

Rear Panel Controls

The CrossPoint 42 HVA has sync termination switches on the rear panel for all
inputs (figure 3-5). The switches provide a way to condition non-TTL sync levels
greater than 5 Vp-p, enabling the sync to be properly passed from input to selected
output(s). The CrossPoint 42 HVA has two sets of sync termination switches; one
for horizontal or combined sync and a second set for vertical sync.

Figure 3-5 — Sync termination switches

Each switch provides the option of selecting either 510 ohms or 75 ohms. The
75 ohms position is required only for an input with non-TTL sync, greater than
5V p-p. The normal (default) position is 510 ohms.

An input that produces an out-of-sync display (a display that is rolling
vertically and/or tearing horizontally) could indicate a non-TTL sync input.
Input should be set to the 75 ohm position for a device known to output non-
TTL sync levels (greater than 5V p-p). If you’re not sure, check the
specifications in the user’s manual for the input device.

Advertising