Extron Electronics XTRA Series User Manual

Page 14

Advertising
background image

3.

Remove the 2 screws holding the hot (Line) and neutral wires from the terminal block
on the PCB (see figure 6).

100-240V

1.3A

50-60Hz

Remove screws
(both sides) to release
IEC connector plate.

Remove nut

Blue Wire

Brown Wire

L

N

Figure 6.

Removing the IEC Connector

4.

Remove the ground wire nut from the grounding stud on the bottom of the enclosure,
as shown above.

5.

Remove the 2 screws from the IEC plate, and remove the IEC connector plate and
the attached wires through the rear panel of the XPA, as shown above.

6.

Thread the 18-gauge power wires through the length of the electrical conduit tube.

7.

Install the EMT adapter plate with conduit attached into the opening from which the
IEC connector was removed in step 5.

8.

Slide the conduit nut over the bundle of wires exiting the conduit and onto the conduit
itself. Hand tighten the conduit nut to the conduit.

9.

Attach the EMT adapter plate assembly to the XPA using the 2 screws that were
removed in step 5.

10.

Connect the black hot (Line) and white neutral wires to the terminal block on the PCB
using the 2 screws that were removed in step 3. Use the included zip tie wrap to
secure the two wires together close to the terminals (see figure 7).

WARNING: Failure to follow these instructions may result in serious

injury.

Ensure that you observe correct wire polarity. The following illustration shows

the location of the hot (Line) and neutral terminals.

LINE

NEUTRAL

L

N

Conduit Nut

EMT Adapter Plate

Terminal Block

Zip-Tie

Ground
Wire Nut

Hot
Terminal (Black)

Neutral
Terminal (White)

Figure 7.

Installing the EMT Adapter Plate Assembly

11.

Secure the ground wire, as shown above, to the grounding stud on the bottom of the
enclosure using the nut that was removed in step 4.

12.

Replace the cover of the XPA by attaching the 8 screws that were removed in step 2.

XTRA Series Half-Rack Audio Power Amplifiers • Installation

8