Remote volume control, Extron stp 22 cable – Extron Electronics XTRA Series User Manual

Page 23

Advertising
background image

h

High pass filter (HPF) toggle switch (XPA 2001 series) — Use a small
screwdriver to toggle this recessed two-position switch. Setting the switch to 80 Hz
(default) prevents the saturation of 70 V and 100 V speaker input transformers by
low frequency signals. Saturation can result in severe distortion of the speaker output
signal.

HPF

80 Hz

OFF

or

80 Hz

HPF

OFF

NOTES:

The filter may be safely turned off if high pass filtering is applied to the
source input signal upstream of the amplifier. Otherwise, it should be left on.

The high pass filter toggle switch may be labeled one of two ways. The
wiring and function are the same, whichever way your product is labeled.

Remote Volume Control

Options for the remote control of the XPA amplifiers include the Extron VCM 100 and
VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be
connected to this port.

As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference voltage.
Pin C (2) is the volume control DC voltage input. The range is 0 to 10 V, where 0 V is mute
and 10 V provides maximum volume. Pin G (3) is ground.

NOTE: All nominal levels are at ±10%.

VOL/ MUTE

10V

Red

Black

Ground

Extron
STP 22
Cable

VOLUME

VCM 100

MUTE

1 2 3 4 5

STANDBY

VOL/MUTE

10V

50 mA

or

REMOTE

G

G

C

V

10V

50mA

ST

ANDBY

Figure 8.

Pinout Diagram for VCM 100 MAAP Connection to XPA Remote