Extron Electronics XTRA Series User Manual

Page 20

Advertising
background image

MUTE

VOLUME

G

10K OHMS

2K OHMS

MAX

2 C

3

1 V

MIN

1 2 3

STANDBY

MUTE SWITCH

VOL/MUTE

10V

50 mA

4 5

or

REMOTE

G

G

C

V

10V

50mA

ST

ANDBY

Pin 5 (standby) connected to ground (pin 4) places the amplifier in standby mode.
Standby mode turns off all output, although the amplifier is still receiving power.
Use the included 2-pin, 3.5 mm captive screw connector to remotely ground pin
5. The power indicator LED lights amber when the amplifier is in standby mode.

Remote Switching to Standby Mode

1 2 3

4 5

STANDBY

VOL/MUTE

10V

50 mA

STANDBY

G

V

G

C

10V

50mA

or

REMOTE

G

G

C

V

10V

50mA

ST

ANDBY

å

Stereo audio output connector — Marked “1” and “2” for the output channels,
wire the included 4-pole, 5 mm screw lock captive screw connector to output stereo
audio. Observe the correct polarities for each channel (see the following steps).The
output is designed to power 4 or 8 ohm speaker systems and is rated for 100 watts
per channel at 4 ohms and 60 watts per channel at 8 ohms for the non-Plus model,
and 100 watts per channel at 4 and 8 ohms for the Plus model.

NOTES:

You must use Class 2 wiring for this output to comply with UL requirements.

The stereo audio output connector may be labeled one of two ways
(see the images on the following page). The wiring and function are the
same, whichever way your product is labeled.

XTRA Series Half-Rack Audio Power Amplifiers • Operation

14

Advertising