Operation, Connections, Figure 2. typical test connections – Extron Electronics FLS 101 User Guide User Manual

Page 10: Fiber optic test meters • operation 4, Fls 101 fiber optic light source, Fpm 101 fiber optic power meter, Extron

Advertising
background image

Operation

This section details the connection of fiber optic cables to the equipment for testing and
measuring the power loss of a fiber optic source.

FPM 101 Power Meter — Controls and Connections

FLS 101 Light Source — Controls and Connections

Measuring Optical Power

Testing Fiber Optic Links

Testing Singlemode Links

Using the Tone Generator

Fiber Optic Test Meters • Operation

4

FLS 101
Fiber Optic
Light Source

Singlemode Fiber under Test

Coupler

or

Bulkhead

Mandrel

Multimode Fiber under Test

FPM 101
Fiber Optic
Power Meter

Transmit Reference

Cable

Receive

Reference Cable

Transmit Reference

Cable

Receive

Reference Cable

FLS 101
Fiber Optic
Light Source

FPM 101
Fiber Optic
Power Meter

Coupler

or

Bulkhead

Coupler

or

Bulkhead

Coupler

or

Bulkhead

9V

850nm 1300nm

1310nm 1550nm

Tone

1310nm
1550nm

850nm

1300nm

CW

CW

FIBER OPTIC LIGHT SOURCE

Extron

dB

dBm

Ref

Set

Extron

Optical Power Meter

WAVE ID

9V

850nm 1300nm

1310nm 1550nm

Tone

1310nm
1550nm

850nm

1300nm

CW

CW

FIBER OPTIC LIGHT SOURCE

Extron

dB

dBm

Ref

Set

Extron

Optical Power Meter

WAVE ID

nm

dB

nm

dB

nm

dB

nm

dB

WAVE ID

nm

dB

nm

dB

850

3.65

1300

4.07

WAVE ID

nm

dB

nm

dB

1310

1.45

1550

1.49

FLS 101

FIBER LIGHT SOURCE

MM

SM

POWER

FLS 101

FIBER LIGHT SOURCE

MM

SM

POWER

POWER

FPM 101

FIBER POWER METER

POWER

FPM 101

FIBER POWER METER

Figure 2.

Typical Test Connections

Advertising