2.

Insert the link to be tested by connecting it to the free ends of the transmit and receive
reference cables using appropriate couplings, or connect the reference cables to the
bulkhead connections of the link as shown in figure 10 below.

NOTE: Clean reference cable and link ends prior to each test.

3.

Observe the displayed values. The link cable insertion loss is displayed in dB.

NOTE: If either the light source or power meter has shut off, turn it back on

and allow to stabilize for a minimum of two minutes.

The two examples in figure 10 below show a multimode and singlemode fiber link being
tested using dual WAVE ID. The insertion loss is displayed in dB.
In the multimode example, the FLS 101 is transmitting both 850 nm and 1300 nm
wavelengths. The FPM 101 has automatically detected the wavelengths using WAVE ID
and is reading a 3.65 dB loss for the 850 nm and 4.07 dB for 1300 nm.
The singlemode example, also using dual WAVE ID, is reading a 1.45 dB loss for the
1310 nm wavelength and 1.49 dB for 1550 nm.

FLS 101
Fiber Optic
Light Source

Singlemode Fiber under Test

Coupler

or

Bulkhead

Mandrel

Multimode Fiber under Test

FPM 101
Fiber Optic
Power Meter

Transmit Reference

Cable

Receive

Reference Cable

Transmit Reference

Cable

Receive

Reference Cable

FLS 101
Fiber Optic
Light Source

FPM 101
Fiber Optic
Power Meter

Coupler

or

Bulkhead

Coupler

or

Bulkhead

Coupler

or

Bulkhead

9V

850nm 1300nm

1310nm 1550nm

Tone

1310nm
1550nm

850nm

1300nm

CW

CW

FIBER OPTIC LIGHT SOURCE

Extron

dB

dBm

Ref

Set

Extron

Optical Power Meter

WAVE ID

9V

850nm 1300nm

1310nm 1550nm

Tone

1310nm
1550nm

850nm

1300nm

CW

CW

FIBER OPTIC LIGHT SOURCE

Extron

dB

dBm

Ref

Set

Extron

Optical Power Meter

WAVE ID

nm

dB

nm

dB

nm

dB

nm

dB

WAVE ID

nm

dB

nm

dB

850

3.65

1300

4.07

WAVE ID

nm

dB

nm

dB

1310

1.45

1550

1.49

FLS 101

FIBER LIGHT SOURCE

MM

SM

POWER

FLS 101

FIBER LIGHT SOURCE

MM

SM

POWER

POWER

FPM 101

FIBER POWER METER

POWER

FPM 101

FIBER POWER METER

Figure 10.

Connections to Measure Link Insertion Loss