Installation, cont’d, Rear panel connectors, Installation – Extron Electronics RCP 2000 User Manual

Page 7

Advertising
background image

RCP 2000 • Installation

Installation, cont’d

RCP 2000 • Installation

Rear Panel Connectors

ETHERNET

LINK

120-240VAC 50/60 Hz

1.2A MAX.

TO SWITCHER

ACT

RS-232

RESET

1

4

3

2

5

Figure 2-1 — RCP 2000 rear panel

1

AC power connector —

Plug a standard IEC power cord from a

100 to 240 VAC, 50/60 Hz power source into this connector.

2

To Switcher port —

This 9-pin female D connector provides for

two-way RS-232 serial communications with the SGS or ISS
switcher. Connect an RS-232 cable from this port to the
switcher’s RS-232 port.

3

RS-232 port —

This 9-pin female D connector provides for two-

way RS-232 serial communication with the computer to control
the RCP 2000.

4

RJ-45 connector —

Connect the RCP 2000 to an ISS 108/408

over an Ethernet LAN using this female RJ-45 connector.

5

Reset button —

Use an Extron Tweeker or a small screwdriver

to press this recessed button to reset the RCP 2000 unit. See
Resetting the Unit in chapter 3 for additional information.

Installation

To install and set up the RCP 2000, follow these steps:

1

Turn all of the equipment off. Make sure that the
ISS 108/408 or SGS 408 and all attached devices are
turned off and, if applicable, disconnected from the power
source.

2

Set the RCP 2000 on a table or other flat surface.

Installation

2-2

3

SGS Switcher:
Attach

one of the RS-232 cables provided with the RCP

2000 between the RS-232 Remote port on the rear panel of
the SGS and the To Switcher port on the rear panel of the
RCP 2000.

ISS Switcher:
Attach

one of the RS-232 cables provided with the RCP

2000 between the RS-232 port on the rear panel of the ISS
and the To Switcher port on the rear panel of the RCP
2000; or attach a network cable between the ISS and RCP
2000 rear panel Ethernet ports.

4

Continue the procedure for installing the ISS 108/408 or
SGS 408.

5

Attach power cords and plug the ISS/SGS seamless
switcher, the input devices, and the output devices into a
grounded AC source.

6

Attach the power cord to the RCP 2000.

7

Select an input using the RCP 2000 top panel Program
input buttons. The image should now appear.

8

If the image does not appear, do the following:

Ensure that all devices are plugged in and receiving
power.

Check the cabling and make adjustments as needed.

Select a different input to check for an image.

2-3

Advertising