2-3

RGB 500 AKM and RGB 560 AKM Installation and Operation

5

Video input termination toggle switch (RGB 500 AKM only)

— The toggle

switch on the front panel allows you to select video input impedance. Set
the toggle switch to the top position for high Z when a local monitor is
connected, or set it to the bottom position for 75 ohm impedance when no
local monitor is connected.

6

DIP switch access cover and DIP switches —

Use a screwdriver to remove

the cover to gain access to the DIP switches. These
eight DIP switches, numbered 1 through 8 from left to
right, control sync on green, sync processing, serration
pulse, composite sync output , force negative sync
options, vertical sync pulse width, and composite

sync routing.

1 — SOG (sync on green)

ON — When this switch is set to On (sync on green), the interface

outputs sync on green.

OFF — When the SOG feature is set to Off, the interface outputs either

separate horizontal and vertical sync signals (on the H/HV
and V connectors) or a composite sync signal (on the H/HV
connector), depending on how DIP switch 4 is set. (Default
setting.)

2 — DDSP (Digital Display Sync Processing)

ON — When this switch is set to On, the interface uses Digital

Display Sync Processing instead of ADSP (Advanced Digital
Sync Processing). Use this option if the image still isn’t
displayed properly after other options (changes to sync width,
serration pulses, and video termination) have been explored.

Turning on DDSP will disable horizontal shift control.

OFF — When this switch is set to Off, the interface uses ADSP.

(Default setting.)

3 — SERR (serration pulse)

Many display devices, including LCD and DLP projectors and plasma
displays, must not have serration pulses in the vertical sync signal in
order to display images properly. Flagging or bending at the top of the
video image is a sign that the serration pulses should be removed.

ON — When this switch is set to On, serration pulses are output.

OFF — When this switch is set to Off, serration pulses are not output.

(Default setting.)

4 — Composite sync output

ON — When this switch is set to On, a composite sync signal (H and

V combined) is output on the black BNC connector.

OFF — When this switch is set to Off, horizontal sync is output on the

H/HV (black) connector, and vertical sync is output on the V
(yellow) connector. (Default setting.)

5 — Force negative H & V sync polarity

ON — When this switch is set to On, horizontal and vertical sync

output are forced to negative.

OFF — When this switch is set to Off, horizontal and vertical sync

follow the input sync polarity. (Default setting.)