Piping, When installing the pump below the tank, Installation – Pump Solutions Group Neptune Solenoid-driven Diaphragm Metering Pump ARPZ-31_61_12 User Manual

Page 14: Important

Advertising
background image

13

Installation

Suction-side joint

Suction valve

Draining of washing water

Suction-side pipe
(downward gradient)

Discharge-side joint

Air-release hose

Relief valve

Relief pipe

Tank

Main pipe

Air-release joint

3-way
valve

Metering
pump

Anti-siphon
check valve
w/ duck-bill cap

Discharge-
side pipe

3-way
joint

Installation is described with an example using ARPZ-31 and TACMINA tank.
• Unlike other models, this pump has a discharge-side joint at the front of the pump head and an air-release side joint on its top.
• It is extremely dangerous for the user to forget to open the valve or for there to be the clogging of foreign matter inside

the pump’s discharge-side pipe. Be absolutely sure to install a relief valve, which will automatically release abnormally
high pressure levels, on the discharge-side pipe.

• Install a valve for releasing abnormal pressure that has built up inside the discharge-side pipe. The 3-way valve on the

washing water line may be used instead.

• To prevent gas lock and other such types of trouble, be absolutely sure to use the pump with a push-in pipe (when the

pump is to be placed lower than the tank).

• In order to prevent gas lock caused by gases generated and building up inside the pipes, make the pipe connections

as short as possible.

Piping

Model w/ automatic air-release function for injection of sodium hypochlorite: ARPZ-31/61/12

When installing the pump

below the tank

✽ Do not install the pump above the tank.
(1) Connect the suction valve of the tank and the suction-

side joint of the pump using the hose. When doing
this, tilt the pipe at a downward gradient so that no air
will be trapped inside the pipe.

(2) Connect the tube to the discharge-side joint of the

pump.

(3) Attach a 3-way joint to the discharge-side tube (near

the pump’s discharge-side joint), and install a relief
valve. Return the end of the relief pipe to the tank or
other container.

(4) Connect the end of the other discharge-side tube

extending from the 3-way joint to the main pipe
(injection point). When doing this, attach the anti-
siphon check valve with duck-bill cap at the injec-
tion-point side end of the hose/tube.

(5) Attach one end of the air-release hose to the air-

release port, and return the other end to the tank or
other container.

✽ If it is unavoidable for the pump to be placed higher

than the tank, be absolutely sure to connect the foot
valve supplied to the end of the suction-side hose
to ensure that no dirt or foreign matter will be mixed
inside the pump head or valve seat.

✽ It is also recommended that a valve, meter, etc. be

installed to make it easy to carry out maintenance
and other such jobs.

IMPORTANT

<Washing water line>
• It is recommended that a washing water line be provided in the piping.

(A 3-way valve for releasing abnormally high pressure levels may be used instead.)

<Sodium hypochlorite>
• Take steps to use up the sodium hypochlorite in as short a period as possible (10 to 20 days in hot weather).
• When diluting sodium hypochlorite, use (1) pure water (purified water), (2) water that has been passed

through a water softener or (3) city water that has been purified.

Metering pump

<Example of unacceptable installation>

07-22_PZ総合取説_E.indd 13

07-22_PZ総合取説_E.indd 13

2008/02/13 8:50:55

2008/02/13 8:50:55

Advertising