Performance curve, Specifications, Pz−31−fec (pp) – Pump Solutions Group Neptune Solenoid-driven Diaphragm Metering Pump ARPZ-31_61_12 User Manual

Page 48

Advertising
background image

47

Specifications

• The performance curves below represent the measurements taken under the conditions prevailing at TACMINA’s test

facilities, and are provided here as examples.

• The individual conditions prevailing on-site and differences between models may produce minor variations from these

curves.

• Measure the discharge volume using the conditions under which the pump will actually be used, and set the stroke

speed in accordance with the applicable performance curve.

Performance curve

Model for injection of general chemicals: PZ-31/61/12-VEC/VFC/FEC/FFC/FTC

PZ−31−

VEC/VFC/FEC/FFC/FTC

PZ−61−

VEC/VFC/FEC/FFC/FTC

PZ−12−

VEC/VFC/FEC/FFC/FTC

Discharge v

olume (L/h)

Conditions: clean water, room temperature

Stroke speed (strokes/min)

0.2

15

0

0.1

120

60

180

300

240

0.3

0.4

0.5

0.6

0.7

0.2MPa (29psi)

1.0MPa (145psi)

Discharge v

olume (L/h)

Conditions: clean water, room temperature

Stroke speed (strokes/min)

0

0.2

1.2

0.8

0.6

0.4

1.0

1.4

0.8MPa (116psi)

0.2MPa (29psi)

15

120

60

180

300

240

Discharge v

olume (L/h)

Conditions: clean water, room temperature

Stroke speed (strokes/min)

0.6

0

0.2

0.4

0.8

1.0

1.2

1.6

1.4

1.8

0.4MPa (58psi)

0.2MPa (29psi)

15

120

60

180

300

240

Model for injection of boiler chemicals: PZ-31-FEC (PP)

PZ−31−FEC (PP)

Discharge v

olume (L/h)

Conditions: clean water, room temperature

Stroke speed (strokes/min)

0.7

0

0.6

0.5

0.3

0.2

0.4

0.1

0.2MPa (29psi)

1.5MPa (217psi)

15

120

60

180

300

240

36-50_PZ総合取説_E.indd 47

36-50_PZ総合取説_E.indd 47

2008/02/01 16:42:48

2008/02/01 16:42:48

Advertising
This manual is related to the following products: