Connecting, Anti-siphon check valve, Installation – Pump Solutions Group Neptune Solenoid-driven Diaphragm Metering Pump ARPZ-31_61_12 User Manual

Page 20

Advertising
background image

19

Installation

Anti-siphon check valve

This pump is provided with an anti-siphon check valve. Use this valve at the injection point unless there is a good rea-
son not to do so. Be absolutely sure to install it in the following cases.
• When the injection point is open to the atmosphere and liquid is to be injected at a position lower than the level of the

liquid in the tank (prevention of siphoning)

• When the liquid is to be injected inside the suction-side pipe of a volute pump, etc.
• When a chemical greatly exceeding the pump’s rated discharge volume is being fed (prevention of overfeed)

✽ Even with a rising pipe, overfeed may occur if the pipe is too long.

• Take care when handling an anti-siphon check valve which is made of PVDF since it is fragile in the face of impact.

(1) The anti-siphon check valve for the FEC(PP) type has an R1/2 external thread. Provide an Rc1/2 internal thread at

the injection point that fits the anti-siphon check valve.

Connecting

(2) Wind sealing tape around the external thread of the anti-siphon check valve, and screw the valve into the injection point.

✽ If it is hard to screw the valve in, grasp the nozzle grip using a tool such as pliers, and tighten the valve gently.

✽ When connecting the tube with the anti-siphon check valve already mounted on it to the main pipe, be absolutely

sure to hold the valve body and turn the nut. If the nut is turned without holding the body, the threaded part on the
nozzle may be damaged.

FEC (w/ PP tube)

FEC (w/ PP tube)

NOTE

<When injecting liquid into a pipe with a small diameter>

If the end of the anti-siphon check valve is too
long, cut it off so that the end will be positioned at
the center of the main pipe where the chemical is
to be injected prior to use.

<For maintenance>

It is recommended that the tube be attached to
the main pipe through a valve to enable the anti-
siphon check valve to be replaced or cleaned, etc.
Use a valve made of materials which will resist

any corrosion resulting from the chemical used.

Anti-siphon
check valve

Valve

Example: FEC (w/PP tube)

Example: FEC (w/PP tube)

Main pipe

Injection point
(Rc1/2)

Nozzle grip

Nut

07-22_PZ総合取説_E.indd 19

07-22_PZ総合取説_E.indd 19

2008/02/13 8:50:57

2008/02/13 8:50:57

Advertising