Maintenance precautions, Maintenance – Pump Solutions Group Neptune Solenoid-driven Diaphragm Metering Pump ARPZ-31_61_12 User Manual

Page 30

Advertising
background image

29

Maintenance

Maintenance precautions

WARNING

!

• Ensure that nobody other than the operators and control personnel will operate the pump.
• Take steps to ensure that the power will not be turned on during the course of work. Hang a sign on the

power switch indicating that work is in progress.

• Do not operate the pump with wet hands. Doing so may result in electric shocks.
• When trouble has occurred (such as when smoke appears or there is a smell of burning), shut down the

pump’s operation immediately, and contact your vender or a TACMINA representative. Otherwise, a fire,
electric shocks and/or malfunctions may result.

• Do not attempt to disassemble the pump body or the circuit parts.

!

CAUTION

• When working on the liquid-end parts of the pump, wear protective gear suited to the chemical

concerned (such as rubber gloves, a mask, protective goggles and work overalls that are resistant to
chemical).

• Before attempting to maintain or repair the pump, release the pressure in the discharge pipe, discharge

the liquid in the pump head, and clean the liquid-end parts.

Check the following points.

Routine inspections

• Check whether the level of the chemical in the tank is high enough.
• Check the pump for chemical leakage.
• Check that the pressure gauge on the pump discharge side indicates a normal value.

Periodic inspections

• At the 10,000-hour mark after starting the pump operation
• When discharge trouble has occurred (reduced discharge

volume)

• When chemical is leaking from around the pump head

Replacing the diaphragm
(see the page 30)

• At the 10,000-hour mark after starting the pump operation
• When discharge trouble has occurred (reduced discharge

volume)

Replacing the valve seats
and check balls
(see the page 31 to 34)

When trouble has occurred

• When the relief-valve function has been activated

Replacing the relief valve
(see the page 35)

• When trouble has occurred during operation

Troubleshooting
(see the page 37 to 38)

29-35_PZ総合取説_E.indd 29

29-35_PZ総合取説_E.indd 29

2008/02/01 9:48:01

2008/02/01 9:48:01