3-5

Chapter 3: BIOS setup

3.3.6

F81866 H/W Monitor

The items in this menu allow you to configure hardware monitoring settings.

Smart Fan Function [Enabled]
Allows you to enable or disable Smart Fan Function. Configuration options:

[Enabled] [Disabled]
Smart Fan Mode Configuration

Fan 1~2 Smart Fan Control [Auto Duty-Cycle Mode]
Select Smart Fan mode. Configuration options: [Auto Duty Cycle Mode]

[Manual RPM Mode] [Manual Duty Mode] [Auto RPM Mode]

Temperature 1~4
Input temperature value to configure fan control. Input value range: [1~100]

Duty Cycle 1~4
Input duty cycle to configure fan control. Input value range: [1~100]

The following item replaces Duty Cycle when Smart Fan Control is set to Auto

RPM Mode.

RPM Percentage 1~4
Input RPM percentage to configure fan control. Input value range: [1~100]

Manual Duty Mode [60]
Input duty cycle value for PWM fan. Input value range: [1~100]

Manual Duty Mode is the only available item when Smart Fan Control is set to

Manual Duty Mode.

Manual RPM Mode [2000]
Input RPM count value for PWM fan. Input value range: [500~10000]

Manual RPM Mode is the only available item when Smart Fan Control is set to

Manual RPM Mode.