Signs of a bad otdr connector – Atec Fluke-OF-500 User Manual

Page 104

Advertising
background image

OF-500 OptiFiber Certifying OTDR
Users Manual

94

Signs of a Bad OTDR Connector

Figure 37 shows traces from OTDRs with good and poor
OTDR port connections. The tester’s OTDR Port

Connection Quality gauge (page 30) lets you know if the
connection is poor. Use a fiber microscope to inspect the
connector for dirt and damage. If the connector is
damaged, contact Fluke Networks for service information.

Increased noise on trace

Increased deadzone and "tailing"

from dirty or damaged

OTDR connection

(especially noticeable on

1300 nm trace)

Minimal deadzone and "tailing"

from good OTDR connection

Minimal noise on trace

ajt34f.eps

Figure 37. Traces Showing Good and Bad OTDR Connectors