Atec Fluke-OF-500 User Manual
Page 125
Specifications
115
Loss/Length Specifications (cont.)
Specification OFTM-5612B
Multimode
Modules
OFTM-5732 Singlemode Modules
Power measurement uncertainty
3
(accuracy)
±
0.25 dB
±
0.25 dB
Measurement linearity
4, 5
(18
°
C to 28
°
C constant temperature)
1300 nm:
±
0.1 dB
850 nm:
±
0.15 dB
±
0.1 dB
Dynamic range for main-remote
communication and nominal length
measurement
12 dB
22 dB
Re-calibration period
1 year
1 year
Display update rate
1 reading per second
1 reading per second
3.
Under the following conditions:
•
Power level: -20 dBm, continuous wave
•
At 850 nm: 62.5/125
µ
m fiber with 0.275 NA
•
At 1310 nm and 1550 nm: 9 /125
µ
m
•
Ambient temperature: 23
o
C
±
5
o
C
4.
Linearity for 1300 nm, 1310 nm, and 1550 nm:
•
Between 0 dBm and -55 dBm:
±
0.1 dB
•
<
-55 dBm:
±
0.2 dB
5.
Linearity for 850 dBm:
•
Between -15 dBm and -52 dBm:
±
0.15 dB typical performance
•
Between 0 dBm and -15 dBm:
±
0.5 dB typical performance