VERIFYING NORMAL OPERATION

1. Turn the power on at the circuit breaker
2. Press the ON/OFF button and press the MODE button to select FAN
3. Cycle through the LO, MED and HIGH fan speeds checking that all speeds run.
4. Set mode to COOL, adjust temp via up/down buttons to approx. 6°F (3°C) less than the
display temp (ie. Room temp) compressor will start within three minutes.
5. Set mode to HEAT, similarly set temp to approx. 6°F (3°C) above display temp.
Compressor will start within three minutes.
After a few minutes the fan will start and warm air will be apparent.
Note: Regardless of the mode selected there will always be at least a 3 minute delay before
the compressor starts.

MAINTENANCE

I. Plenum Filters
The plenum filters are the only parts that require routine maintenance.
They must be cleaned periodically to ensure that they do not become clogged
with dust and other particles and not covered by Warranty.
To clean the two plenum filters, first remove them both from the plenum by
pulling them out of the assembly.

Fig 17 shows the plenum filter when removed.

The state of the filters can be ascertained from its appearance, the filters
are translucent, and if they appear clogged then they should be cleaned.
Generally the filters can be cleaned sufficiently by tapping them together to
shake loose the dust and particles trapped inside.

WARNING

Airborne particles can pose a health risk,

particularly to young children and the elderly.
Ensure that filters are cleaned in a safe and well
ventilated area.

If a more thorough cleaning is required then the filters can be washed out
using warm soapy water. Care must be taken to avoid ripping the fabric.
The filters should be cleaned every two weeks or more when in use.
Prolonged use, higher concentrations of airborne particles, and various
other factors may result in the filters needing to be cleaned more often.
Replacement filters can be ordered directly from Atwood Mobile Products,
LLC by calling 866-869-3118.
II. Mounting Bolts
Atwood suggests that the hold down bolts are initially checked for tightness within
the first 3 months of installation, and thereafter every 12 months if the vehicle is in
constant use.
III. Storage
The air conditioner should be run on a routine basis to ensure the components
remain in working order.
If the vehicle is in storage or is to remain unoccupied for an extended length of
time it is recommended than the air conditioner is allowed to run uninterrupted for
20-30min once every six months.