OPERATING INSTRUCTIONS FOR ADJUSTING THE THERMOSTAT (cont)

7. On/Off timer setting

 When the system is on, setting the timer will turn off the unit after the programmed hours were

counted down. When the system is off, setting the timer will turn on the unit after the programmed
hours were counted down.

 Press

TIMER

button once to activate on/off timer programming mode. Timer LED and temperature

display area flash for 3 seconds showing the number of count down hours left. Thereafter, Timer LED
flashes and temperature display area shows the timer setting.

 Press

TIMER

again to set the timer from 1 to 24 hours in 1 hour incremented in a round robin pattern.

 Hold down this key will change the timer setting automatically every half second.

 Press

TIMER

until the display shows

“—“ will cancel the timer setting.

 Should there be no further button press, system will exit from on timer programming mode

automatically.

 Timer LED will light up if on/off timer is set.

 Press

ON/OFF

to start or stop the air conditioner will also cancel the timer setting.

8.

Error code display

 Should there be any fault happen with the main board, the relevant error code will be shown on the

temperature display area.

 If there is multiple faults happen at the same time, the error code will be shown one after another.

 System will alternate the display of error code and room temperature.

 Depends on the model of main board, the error codes available are:

Fault

Error code

Room sensor failure

E1

Indoor coil sensor failure

E2

Outdoor coil sensor failure

E3

Insufficient of refrigerant

E4

Compressor overload

E5

Not used

E6

Not used

E7

Outdoor air sensor failure

E8

Wall pad room sensor failure

E9