atwood Air Conditioners (non-ducted AC-1351, AC-1501) User Manual
Page 15
AC IOM 3/01/2013 rev 1
15
OPERATING INSTRUCTIONS FOR ADJUSTING THE THERMOSTAT (cont)
7. On/Off timer setting
When the system is on, setting the timer will turn off the unit after the programmed hours were
counted down. When the system is off, setting the timer will turn on the unit after the programmed
hours were counted down.
Press
TIMER
button once to activate on/off timer programming mode. Timer LED and temperature
display area flash for 3 seconds showing the number of count down hours left. Thereafter, Timer LED
flashes and temperature display area shows the timer setting.
Press
TIMER
again to set the timer from 1 to 24 hours in 1 hour incremented in a round robin pattern.
Hold down this key will change the timer setting automatically every half second.
Press
TIMER
until the display shows
“—“ will cancel the timer setting.
Should there be no further button press, system will exit from on timer programming mode
automatically.
Timer LED will light up if on/off timer is set.
Press
ON/OFF
to start or stop the air conditioner will also cancel the timer setting.
8.
Error code display
Should there be any fault happen with the main board, the relevant error code will be shown on the
temperature display area.
If there is multiple faults happen at the same time, the error code will be shown one after another.
System will alternate the display of error code and room temperature.
Depends on the model of main board, the error codes available are:
Fault
Error code
Room sensor failure
E1
Indoor coil sensor failure
E2
Outdoor coil sensor failure
E3
Insufficient of refrigerant
E4
Compressor overload
E5
Not used
E6
Not used
E7
Outdoor air sensor failure
E8
Wall pad room sensor failure
E9