95

Performance Tests Results

Setting

Minimum reading

Maximum reading

Reading

Frequency DDS

1 MHz

999980 Hz

1000020 Hz

Frequency ARB

1 MHz

999950 Hz

1000050 Hz

Sine Amplitude

10Vp-p

3.499V

3.572V

5Vp-p

1.749V

1.786V

3Vp-p

1.049V

1.072V

1Vp-p

0.349V

0.358V

100mVp-p

34 mV

37 mV

50mVp-p

17 mV

19 mV

Square Amplitude

10Vp-p

4.949V

5.051V

5Vp-p

2.474V

2.526V

3Vp-p

1.484V

1.516V

1Vp-p

0.494V

0.51

100mVp-p

49 mV

52 mV

50mVp-p

24 mV

26 mV

ARB Amplitude

10Vp-p

3.499V

3.572V

5Vp-p

1.749V

1.786V

3Vp-p

1.049V

1.072V

1Vp-p

0.349V

0.358V

100mVp-p

34 mV

37 mV

50mVp-p

17 mV

19 mV

Offset Accuracy

+4V

3.950V

4.050V

+2V

1.970V

2.030V

0V

-10mV

+10mV

-2V

-1.970V

-2.030V

-4V

-3.950V

-4.050V

Sine Distortion

1 KHz

- 65 dB

Square Transition

1 MHz

12 ns

Variable Duty Cycle

20%

19.00%

21.00%

50%

49.00%

51.00%