Syntax: *PSC?
Response: ASCII 0 for OFF

ASCII 1 for ON

When set to ON (1), the Service Request Enable Register and the Standard Event Status Enable Register
are cleared on power-on.



e) *SRE - Service request enable command


This command sets the Service Request Enable Register bits.

Arguments
Type: NRf
Range: 0 to 255. Non integer arguments are rounded before execution.

The value of bit 6 is ignored, and is set always to zero.

Type:

Common Command or Query

Command
Syntax: *SRE<ws><NRf>
Examples: *SRE 48 (Enables reporting of ESB and MAV events)
Query
Syntax: *SRE?
Response: <NR1>


f) *STB? - Status byte query


This query is used to read the value of the Status Byte.

Type:

Common Query

Syntax: *STB?
Response: <NR1>

The value of the Status Byte read with the *STB? query may differ from that read with the Serial Poll. Bit 6
of the STB will be set as long as a reason for requesting service exists, while bit 6 of the STB as read by the
Serial Poll is cleared by the Serial Poll.


4.12.5 Device Trigger Commands


a) *TRG - Trigger command

This command is analogous to the IEEE 488.1 Group Execute Trigger interface message, and has the same
effect. It is used to trigger the device to output a wave, and is accepted only when the trigger mode is set to
Trigger, Gate or Burst, and the trigger source is set to BUS.

Type:

Common Command

Syntax: *TRG

4.12.6 Stored Settings Commands


a) *RCL - Recall instrument state


This command is used to restore the state of the device to that stored in the specified memory location.