Measure signal frequency

Input the signal to channel 1.

Press the “AUTO” button.

● Press the “MEASURE” button to see “auto Measure Menu”.

● Press the top option button.

● Press the “Time” option button to enter the “Time Measure menu”.

● Press the “Source” option button to select input signal channel.

Press the “Type” option button to select “Freq”

.

The corresponding icon and measure value will display on the

third option area.

Measure signal peak-to-peak amplitude

● Press the “MEASURE” button to display “auto measure menu”.

● Press the top second option button.

Press the “Voltage” option button to enter the “Voltage measure menu”.

● Press the “Source” option button to select input signal channel.

● Press the “Type” option button to select “Vpp”.

The corresponding icon and measure value will display on the third option

area.