B&K Precision 1856D - Manual User Manual

Page 12

Advertising
background image

12

FIG.2 FRONT PANEL

GATE INDICATOR:

The gate light, when lit, indicates the main gate is open

and measurement is in progress.

RS-232C INDICATOR: TX (transmitting), RX (receiving) blinking

OVER FLOW INDICATOR: OF is displayed when there is an overflow.

DISPLAY: 9 digit (0

.56“) green LED display used for all readings.

NOTE: LAST MEASUREMENT DISPLAY WILL REMAIN FOR 10 SECONDS

AFTER SIGNAL OFF.

UNIT INDICATOR:

When lit, indicates that the frequency displayed is in

MHz, KHz, Hz and period is in nano, micro, or milli

(n/u/m) Sec.

HOLD INDICATOR:

The HOLD function is engaged the when lit.

INPUT C:

Use this input for all frequency measurements above 80

MHz. Female N type connector terminated in 50

.

LOW PASS FILTER: With this switch pushed in, the A input is routed through

a low-pass filter with a -3 dB point at approximately 100

KHz. When it is released, the A input is applied directly

to the counter.

ATT. SWITCH:

When this switch is set to x10 (pushed in) the A input is

attenuated 10:1 before application to the counter. With

the switch set to x1 (pushed out), the A input signal is

applied unattenuated. The attenuator has no effect on

the C input.

COUPLE. SWITCH:

This switch is used to select the input coupling

mode, AC or DC.

INPUT A:

Use this input for frequency measurements below 100

MHz and all period measurements. Female BNC

connector. Input impedance is1 M

shunted by < 40