Series 98 Operation & Maintenance



Module. Pull off the module carefully so as not to damage
the threads on the Spring Rod and the Adaptor Plate Studs.

6.3.2 Service & Reassembly of the Spring Module



from the cover end.



the Spring Rod and slide it back in.







6.4 Pressure Module

CAUTION

Ensure the ports are vented to atmosphere before disassembly
of Pressure Module. Failure to do so could cause severe injury.

To take the Pressure Module off the Spring Return Actuator,
first the Spring Module must be removed or at least the Spring
Rod must be disconnected from the Guide Block (steps 1-3), as
described in section 6.3.1.

If the actuator is provided with a Jackscrew or Extended Travel
Stop on the Pressure Module, first ensure to back them off fully
and remove them from the Pressure Module by unfastening the
bolts holding the assembly on the End Cap.

6.4.1 Removing the Pressure Module from

Actuator





Piston Rod (35) from the Guide Block (25) in Torque
Module.



now be pulled off the Torque Module. Pull off the module
carefully so as not to damage the threads on the Piston Rod
and on the Adaptor Plate Studs.



groove.

6.4.2 Disassembling the Pressure Module





with a plastic mallet and remove the End Plate.



(31) and Piston (33), being careful not to scratch or dent the
honed and chrome plated surface of the barrel.



not to damage the threads.





off the Piston Rod (35) upper groove. Pull the Piston Rod
off the Piston and remove the Split Collars from the lower
groove.

6.4.3 Service & Reassembly of the Pressure

Module

NOTICE

The wear parts (all seals, piston wear bands and rod guide
bushings in the Repair Kit) shall be replaced during the
maintenance cycle. Ensure the replacement seals are suitable
for the service temperature

The assembly of the Pressure Module is done in vertical
orientation.

Use Dow Corning Molykote 55 lubricant in the Pressure Module.



below, to accommodate the Piston Rod. The rod seal groove
side of the Adaptor faces upwards.



groove in Adaptor Plate with the seal lip towards piston side.





on the piston rod.



groove and slide in the Piston Rod (hex side) through the
Piston till the split collars locate in the counter bore in the
piston.



secure it by the Spiral Retainer Ring.



Assembly through the Rod Seal and Guide Bushing in the
Adaptor Plate. Beware of the pinch points between the
Piston and the Adaptor plate while lowering the Piston
Assembly on the Adaptor Plate inner face.



Quad Seal (43) on the Piston.

Advertising