54 Appendices

Characteristics

Input Characteristics

Analogue Voltage Inputs

Suitable for

Potentiometers
Voltage output sensors
Variable resistance sensors with pull-up
resistor

Measure Voltage Range

Inputs: 0 to 5.46 V
Note: Voltages outside this range may affect
the readings on other inputs.

Input Resistance

100k ohms to 0 V

Resolution

Inputs: 1.33 mV

Measurement Methods

Ratiometric
Absolute
Variable Resistance Off/On

Update Rate

1000 times/second

Filter

240 Hz 1st order

Calibration Accuracy

Gain 0.05% max (Ratiometric method)
Gain 0.15% max (Absolute method)
Offset 6 mV max
Linearity 6 mV max
Temperature Stability 60 ppm/°C max
Calibration Schedule 12 months