20 Amp Outputs

Number of 20 A outputs

PDM16

PDM32

PDM15

PDM30

8

8

8

8

Maximum output current

20 A continuous, 115 A transient (typical)

Over-current shutdown

Programmable in steps of 1 A

Protection

Short circuit and thermal overload
protection

Inductive load clamp voltage

17 V (relative to Batt)

Maximum inductive load
energy

1.5 J (junction temperature = 150 °C, load
current = 20 A)

8 Amp Outputs

Number of 8 A outputs

PDM16

PDM32

PDM15

PDM30

8

24

7

22

Maximum output current

8 A continuous, 60 A transient (typical)

Over-current shutdown

Programmable in steps of 1 A

Protection

Short circuit and thermal overload
protection

Inductive load clamp voltage

Output 9:

0.7 V (relative to Batt)

Other Outputs:

42 V (relative to Batt+)

Maximum inductive load
energy

0.3 J (junction temperature = 150 °C, load
current = 20 A)

Inputs

Number of inputs

PDM16

PDM32

PDM15

PDM30

12

23

16

16

Pull-up resistor

10 kilo ohm to Batt+

Measurement

Range of 0 to 51 V, resolution 0.2 V
(8 bits)

Calibration

High and low trigger voltage, high and low
trigger times

CAN Input

Number of messages

4 messages, 8 bytes per message

CAN Output

Message rate

20 Hz