GB
6.4.2 - Diameter gauge
Place the gauge on the brush as shown in the fi gure and press
- The number 341 ± 1° appears on the left display .
- Position the distance gauge 20 mm from the edge of the brush as
shown in the fi gure
- The number 272 ± 3° should appear on the left display.
- If not, press the button
holding the gauge still at 20 mm:
the number 272 appears on the left display.
- Return the gauge to rest position.
In the event of incorrectly accessing the diameter gauge
calibration function, press
to cancel it.