6.4.2 - Diameter gauge

Place the gauge on the brush as shown in the fi gure and press

- The number 341 ± 1° appears on the left display .

- Position the distance gauge 20 mm from the edge of the brush as
shown in the fi gure

- The number 272 ± 3° should appear on the left display.

- If not, press the button

holding the gauge still at 20 mm:

the number 272 appears on the left display.
- Return the gauge to rest position.

In the event of incorrectly accessing the diameter gauge

calibration function, press

to cancel it.