CHIEF CM2C40 User Manual
Page 18
CM2C40
Installation Instructions
18
IR-SE15 Programming
IR-SE15 Control Features:
•
Carrier Frequency:38KHz
•
Protocol:NEC - Full Repeat
•
System Code(s):6E (Default) - Multiple Codes
Selected via Key-Press (see below)
To Change System Code:
1.
Press and Release Key 3 + 7 (Enter Setup Mode)
2.
Press and Release Key 10
3.
Press and Release Key 11 - LED Blinks Twice <Quick>
4.
Select System Code - See Table Below
5.
Press and Release Key 2 - LED Blinks 4 times <Quick>
(Exit Setup Mode)
Figure 29
Table 2:
System
Code
Press + Release
6E (Default)
10, 10
E1
10, 13
E2
11, 11
E3
11, 12
E4
11, 13
E5
12, 12
E6
12, 13
E7
13, 13
Table 1: IR-SE15 Control Codes
KEY