CHIEF CM2C40 User Manual

Page 19

Advertising
background image

Installation Instructions

CM2C40

19

Serial Communications

NOTE:

Check with the appropriate automation system vendor

for available drivers and/or software for any external
devices.

Notes:

[PR] = Product ID (CM2C40 = 02)

[AD] = Address (see address description & table)

[CR] = ASCII Carriage Return

[CH] = Check Code

[ST] = Status (see status table)

Connections to be made to 9 pin connector as follows:

Communication parameters as specified in ANSI TIA/EIA-485-A:

Address Description

Multiple Chief devices can be used on the same network by
setting each device to a different address.

NOTE:

All units ship with a default address of 00.

NOTE:

Broadcast messages will command all devices on the

same network.

RS-485 REF

Pin 7

RS-485 +

Pin 9

RS-485 -

Pin 8

Baud Rate:

9600

Data Length:

8 Bits

Parity:

None

Stop Bit:

1

Flow Control:

None

SERIAL CONTROL COMMAND STRING

Product ID for the CM2C40: 02

Address controlled by dip switch settings

Basic Commands available for the CM2C40 in the factory-supplied configuration:

03: Cancel Move = >0500037D[Carriage Return]

10: Extend to End of Travel = >0500107B0D[Carriage Return]

12: Retract to End of Travel = >0500127D0D[Carriage Return]

Message Data = The data is required for the available commands:

03: None

10: None

12: None

Check Code is calculated.

For further information, reference the Advanced Programming document and the website calculator.

Start of

Message
(HEX)

Product ID

(HEX)

Address

(HEX)

Command

(HEX)

Message

Data
(HEX)

Check Code

(HEX)

End of Message

(HEX)

>

XX

XX

XX

XX

XX

[Carriage Return]

Advertising