Input/output pin control, Outputs, Input/output pin control outputs – ALLIED Vision Technologies Bigeye G-1100 Cool User Manual

Page 44

Advertising
background image

Camera interfaces

Bigeye G Technical Manual V2.1.0

44

Input/output pin control

All input and output signals running over the camera I/O connector are con-
trolled by the I/O strobe commands. See AVT GigE GenICam Feature Descrip-
tion
and AVT GigE Vision Cameras.

Outputs

Output features are configured by software. Any signal can be placed on any
output.

The main features of output signals are described below:

Note

For a general description of the outputs and warnings see the
AVT GigE Installation Manual.

Signal

Description

GPO

Configured to be a general purpose output, control
of which is assigned to SyncOutGpoLevels.

AcquisitionTriggerReady Active once the camera has been recognized by the

host PC and is ready to start acquisition.

FrameTriggerReady

Active when the camera is in a state that will accept
the next frame trigger.

FrameTrigger

Active when an image has been initiated to start.
This is a logic trigger internal to the camera that is
initiated by an external trigger or software trigger
event.

Exposing

Exposing – active for the duration of sensor expo-
sure.

FrameReadout

Active at during frame readout, i.e. the transfer-
ring of image data from the CCD to camera memory.

Imaging

Imaging is high when the camera image sensor is
either exposing and/or reading out data.

Acquiring

Active during an acquisition stream.

SyncIn1

Active when there is an external trigger at SyncIn1.

SyncIn2

Active when there is an external trigger at SyncIn2.

SyncIn3

Active when there is an external trigger at SyncIn3.

SyncIn4

Active when there is an external trigger at SyncIn4.

Strobe1

The output signal is controlled according to Strobe1
settings.

Table 12: Output signals

Advertising