Determines configuration
of hotkeys in conjunction
with switch 

Reserved for
future use

OFF: Normal operation
ON: Flash upgrade

Determines configuration
of hotkeys in conjunction
with switch 

Note: When shipped, all switches are set in the OFF positions and this will
produce normal operation.

X200 module switches

Certain aspects of operation can be affected by the switches on the X200
module.

Switch 
OFF: Normal operation.
ON: (Before power is applied) Places the X200 module into flash upgrade

mode so that the internal software can be changed. Please see the

Flash.

upgrade

section in the ‘Special configuration’ chapter.

Switches  and 
Switches 2 and 3 determine which two keyboard keys (when pressed in unison)
are to be designated as ‘hotkeys’. Hotkeys signal to the X200 module that the
next key to be pressed is a special configuration command for the module and is
not to be passed to the computer system.
2 OFF
3 OFF

Hotkeys = CTRL and SHIFT

2 OFF
3 ON

Hotkeys = ALT and SHIFT

2 ON
3 OFF

Hotkeys = CTRL and ALT

2 ON
3 ON

Hotkeys disabled

Switch 4

This switch is reserved for future use.