Flowline LI40-1001 PodView User Manual

Page 6

Advertising
background image

6 of 16 

MN204260 

Rev A 

WIRING 

Step Five 

Wiring PodView® to EchoPod®:  PodView® and EchoPod® require a 12 to 28 VDC power supply to operate.  
The maximum cable distance between PodView® and EchoPod® is 15’ (4.5m).  Follow the below steps to wire 
EchoPod® with EchoPod®: 

 

EchoPod® 

 

 

PodView® 

Wiring identical for all series of EchoPod®.  Use only the Red, Black, Green and White wires. 

1. Connect the Red and Black wires of both PodView® and EchoPod® to the 12‐28 VDC power supply. 

2. Connect  the  Green  and  White  wires  of  PodView®  to  the  corresponding  Green  and  White  wires  of 

EchoPod®.  

3. Isolate the Green and White wires from active power to prevent a short of the configuration circuit. 

Adding a Loop Powered Display 

 

General Safety 

 Where personal safety or significant property damage can occur due to a spill, the application must 

have a redundant backup safety system installed. 

 Wiring should always be done by a licensed electrician. 
 Supply voltage should never exceed 28 VDC. 
 Protect the sensor from electrical spikes by isolating the power. 
 Design a fail‐safe system for possible indicator and/or power failure. 
 Never use the sensor in environments classified as Hazardous