3-14

Section 3 Operation

Installation and Operation Manual

X-PD-BM-Ovals-eng

Part Number: 541B031AAG

January, 2009

BM Oval Series

3-9 Deluxe LCD Specifications

The Deluxe Liquid Crystal Display

Measuring Unit:
Can be set to Liters, US Gallons, or Imperial Gallons.
Imperial Gallons = "IMP GAL" = 4.5460 Liters
US Gallons = "US GAL" = 3.7854 Liters

Calibration Constant:
10 different constants can be recorded.
Each constant can be set by keys within the range of 0.0000 to 0.99999.
Only the 4 points after the decimal point are displayed.

Partial Quantity Counter:
7-Digit Display;

999999.9 Liters Maximum
999999.9 Gallons Maximum

No overflow indication (the counter starts again at zero).
Resettable to zero by special combination of keys only.

Totaliser:
7-Digit Display without decimal point;

9999999 Liters Maximum.
9999999 US Gallons Maximum.

Automatic Range Presetting:
To be set to 99.99, 999.9 or 9999 Liters/Gallons.
(Relative Automatic Operation)

Preset Quantity:
10 different preset quantities can be set.
The preset quantity can be within the predetermined range
(Automatic range of presetting).
(Relative Automatic Operation)
If the preset quantity is changed, this counter will reset to zero
automatically.

Figure 3-8 Deluxe LCD