4-7

Section 4 Maintenance

BM Oval Series

Installation and Operation Manual
X-PD-BM-Ovals-eng
Part Number: 541B031AAG
January, 2009

To extend battery life it is advised to disable unused functions.
Check periodic:
• The condition of the casing and front panel.
• The wiring of components for reliability and ageing symptoms.
• The process accuracy. As a result of wear and tear, re-calibration of the

flowmeter might be necessary. Do re-enter any subsequent K-factors
alterations.

• The indication for low-battery.
• Clean the casing with soap-water; don’t use any aggressive solvents as

these might damage the polyester coating.

Technical Specifications General:

Display: High intensity reflective alphanumeric LCD, UV-resistant.

Digits: Seven 17mm (0.67") and eleven 8mm (0.31"). Various symbols and

measuring units.

Refresh rate: Selectable via menu: 8 times/sec - 30 sec’s.

Window: Polycarbonate window.

Control keys Three industrial micro-switch keys. UV-resistant polyester

keypad.

Operating temperature: -20°C to +70°C.

Power requirements: 8-30 Vdc supply can be connected to power the unit.

Option PA: Internal Lithium battery 3.2 Vdc: average lifetime seven years

dependent upon settings and sensor type.

Sensor excitation: Same voltage as offered to power the unit.

Terminal connections: Removable plug strip. Wire max. 1.5mm2.

Data protection: EEPROM backup of all setting. Backup total and

accumulated total every minute.

Environment CE: EMC compliant ref: EN50081 and EN50082.

Pulse inputs: Type P: NPN, reed-switch,
Frequency: Minimum 0 Hz - maximum 7 kHz for total and flowrate. Max
frequency depends on signal type and internal low-pass filter, see Section

3.2.3.5. Reed switch with low-pass filter = max. 120 Hz.

Low-pass filter: Available for all pulse signals.

Selection main function: Total or Flowrate will be displayed with 17mm

digits.

Operator Functions

General: The Operator has three functions available:

- TOTAL and Flowrate are displayed.

- TOTAL can be reset by pressing CLEAR-key twice.

- After pressing SELECT, Accumulated TOTAL will be displayed.
TOTAL: 17mm character-size - 7 digits. Measuring units: L, m3, GAL,
USGAL, KG, lb, bbl, no unit. K-factor: 7 positions 0.000010 - 9,999,999.

Number of decimals: max. three. TOTAL is resetable.
Accumulated Total: 8mm character-size - 11 digits. Acc. Total is not
resetable. Uses the same K-factor, unit and decimals as TOTAL.

Advertising