Installation 7, Application conditions 6.2, Conformity 6.3 – Burkert Type 6211 User Manual

Page 4: Rating plate description, Safety instructions 7.1

Advertising
background image

12

Application conditions

6.2.

Allowable temperatures
Ambient temperature:

max. +55 °C

Heat-radiating energy sources must not additionally heat
the unit.

Permitted medium temperature depending on seal material:

FKM / NBR

0 ... +70 °C

EPDM

-30 ... +70 °C

Permitted medium temperature depending on seal material:

Seal material

Permitted media

FKM / NBR

Diesel and heating oil without addi-
tives, water, compressed air

EPDM

Oil and grease-free liquids and gases,
cold and hot water

Operating duration
Unless otherwise indicated on the rating plate, the solenoid
system is suitable for continuous operation.

Important information for functional reliability during
continuous operation!
If switched on for a long period, it is recommended
to activate the valve 1-2 per day.

english

13

Service life
High switching frequency and high pressures reduce the
service life.

conformity

6.3.

CE mark conforms to EMC Directive 2004/108/EEC only if
cables, plugs and sockets connected correctly.

6.4. rating plate description

Rating plate

Location of the rating plate

Fig. 1:

english

14

rating plate

6.4.1.

6211EV A 10 EPDM MS

M

a

d

e

in

G

e

rm

a

ny

00214242

W1X LU

230V 50-60Hz 4W

G 1/2 P

N 0,5

-

10 bar

Type

Operating

prinziple

Orifice

Seal material

Housing material

Identification

number

Manufacturer - code

Voltage, frequency, power

consumption

Connection thread, nominal

pressure

Example:

english

15

insTallaTiOn

7.

safety instructions

7.1.

Danger!

Risk of injury from high pressure in the equipment!

Before loosening the pipes and valves, turn off the

pressure and vent the pipes.

Risk of injury due to electrical shock!

Before reaching into the device or the equipment,

switch off the power supply and secure to prevent

reactivation!
Observe applicable accident prevention and safety

regulations for electrical equipment!

Warning!

Risk of injury from improper installation!

Installation may be carried out by authorized technici-

ans only and with the appropriate tools!

Risk of injury from unintentional activation of the
system and an uncontrolled restart!

Secure system from unintentional activation.

Following assembly, ensure a controlled restart.

english

Type 6211 EV

Advertising