20

installation of coil

8.2.

Warning!

Escaping medium!
When a sticking nut is loosened, medium may escape.

Do not tighten sticking nut any further.


Electric shock!
If the protective conductor is not connected, there is a
risk of electric shock!

Check protective conductor contact after installing the

coil.

Overheating, risk of fire!
Connection of the coil without pre-assembled valve will
result in overheating and destroy the coil.

Connect the coil with pre-assembled valve only.

Installing the coil:

Warning!

Danger due to electrical shock if coil incorrectly
installed!

During installation ensure that the coil is situated firmly

on the housing cover so that the protective conductor

connection of the coil is connected to the valve housing.

english

21

Connect coil housing to the core guide pipe.

Screw on coil with nut.

note!

Device will be damaged if the wrong tools are used!
Always use a wrench to tighten nut. If other tools are used
(e.g. pliers), the device may be damaged.

Nut

Core guide tube

O-ring

Locking pin

Installing the coil

Fig. 3:

english

22

Torque 2.8 Nm

Torque

Fig. 4:

malfunctions

8.3.

If malfunctions occur, check whether:

the device has been installed according to the

instructions,
the electrical and fluid connections are correct,

the device is not damaged,

all screws have been tightened,

the voltage and pressure have been switched on,

the pipelines are clean.

english

23

Valve does not switch
Possible cause:

Short-circuit or coil interrupted.

Core or core area dirty.

Medium pressure outside the permitted pressure range.

Valve does not close
Possible cause:

Internal space of the valve is dirty.

Small control bore in the diaphragm blocked.

Diaphragms defective.

english

Type 6211 EV