Port set command – Avocent CCM1640 User Manual

Page 64

Advertising
background image

58

CCM840/1640 Installer/User Guide

Port Set command

The Port Set command changes CCM port settings in the CCM configuration

database. At least one keyword parameter and value must be specified. For more

information, see Configuring Serial Port Settings in Chapter 3.

Access right: SCON or PCON

Access level: ADMIN or APPLIANCEADMIN

Syntax

PORT

[<port>|ALL] SET

[TD=<device>] [NAME=<name>] [BAUD=<baud>] [SIZE=<size>]

[PARITY=<parity>] [STOP=<stopbits>] [FLOW=<signal>]

[TIMEOUT=<time-out>] [SOCKET=<socket>] [CHAR=^<cli_char>]

[TOGGLE=NONE|DTR]

[POWER=<signal>]

Port Set Command Parameters

Parameter Description

<port>|ALL

Either a port number in range 1-8 for a CCM840 or 1-16 for a
CCM1640, or All which indicates that the settings that follow should
be applied to all ports.
Default = port to which you are attached

TD=<device>

Target device type. Valid values are Console and SPC. The SPC
value is reserved for future functionality.
Default = Console

NAME=<name>

Port name, up to 32 characters. If the name contains spaces, enclose
the name in double quotes. To return one or all port names to default
values, specify Name=“”. The port name is used only by AVWorks.
Default = last 3 octets of MAC address plus the port number

BAUD=<baud>

Baud rate. Valid values are:
0, 75, 110, 134, 150, 200. 300, 600, 1200, 2400, 4800, 7200,
9600, 14400, 19200, 28800, 38400, 57600, 115200.
Default = 9600

SIZE=<size>

Number of data bits per character. Valid values are 7 and 8.
Default = 8

PARITY=<parity>

Parity. Valid values are:
None

No parity.

Even Even

parity.

Odd Odd

parity.

Mark Mark

parity.

Space Space

parity.

Default = None

STOP=<stopbits>

Number of stop bits per character. Valid values are 1 and 2.
Default = 1