Burkert Type 1094 User Manual

Page 3

Advertising
background image

3

Information on the replacement

of the electronic control

Pin assignment for replacement of the ident. no. 130561

GND

Diesel 2

GND

Impuls 2

GND

Diesel 1

GND

Impuls 1

+ Input

Frequency input
Gasoline pulse
Side 1

GND

+ Input

Diesel identifier
Side 1

GND

+ Input

Frequency input
Gasoline pulse
Side 2

GND

+ Input

Diesel identifier
Side 2

GND

Assignment of gas recovery
Inputs

is replaced by ident. no. 208373 and

ident. no. 770156 (power supply unit)

+ 15 V

Input B (+)

Input B (–)

Input A (+)

Input A (–)

Valve B (+)

Valve B (–)

Valve A (+)

Valve A (–)

Pump B (+)

Pump B (–)

Pump A (+)

Pump A (–)

230 V

115 V

N

L1

Operating voltage

Selection 230 V / 115 V

Connection

Power supply unit

LEDs

LEDs

Old ident. no. 130561

+ 24V

GND

+

+

+

+

Ventil 1

Schütz 1

Ventil 2

Schütz 2

GND

Motor contactor
control
Side 2

+ Output

GND

Valve control
Side 2

+ Output

GND

Motor contactor
control
Side 1

+ Output

GND

Valve control
Side 1

+ Output

GND

24 V supply

+ Output

Outputs

Power supply unit
ident. no. 770156

Ident
ification

Pin assignment

+

24 V

Output voltage

GND

L

100 V AC to
240 V AC

Operating
voltage

N

Important!
Connect the power supply unit,
as illustrated on the right, to the
24 V supply.

Protective conductor

Overview of assignment: Old → New

Pin assignment (old)

Labeling

Pin assignment (new)

+ 15 V

No longer available

Input B (+ and –)

→ Impuls 2 / GND Frequency input of gasoline pulse, side 2

Input A (+ and –)

→ Impuls 1 / GND Frequency input of gasoline pulse, side 1

Valve B (+ and –)

→ Ventil 2

Control of valve, side 2

english

Type 1094