English – Burkert Type 1094 User Manual

Page 10

Advertising
background image

8 - 1094

english

3.4 Outputs

Output transistor

Positiv-switching transistor

Load current

0 to 250 mA

Output voltage

24 V DC

Clock frequency

270 Hz

Number of outputs

One valve output each for + and -

Output for the proportional valve

To regulate the Type 2832 proportional vlave, the controller outputs a current-regu-
lated PWM signal via a transistor.

Output for the control of the vaccum pump motor

Output transistor

„Open-Collector“ transistor output

Load current

100 mA

Output voltage

24 V DC

Special freatures

Freewheeling diode, after-run time adjustable (in con-
nection with the manual control unit Type MKNE-1094)

Number of outputs

One pump output each for + (24 V) and – (GND)

The „open-collector“ output shown in Figure 4 is used for the control of a relay/con-
tactor for switching the vacuum pump motor.
The „open-collector“ output is switched active by the controller as long as the propor-
tional valve is open.

from CPU
(Port Bx)

2.2 k

+ 24 V

Output

BC 337 or similar

10 k

Figure 4: "Open-Collector" transistor output to the pump controller

Advertising