3 TECHNICAL DESCRIPTION

3.1 General technical data

Ambient temperature

-25 °C ... +85 °C

Dimensions

68 x 76 x 35 mm

Housing

Open housing for mounting on mounting rails according
to DIN EN 50 022 / DIN EN 50 035 / DIN EN 50 045

Protection class

IP 20

Order No.

060 651

3.3 Inputs

Frequency input of the controller

High level impulse

2.5 V ... 25 V

Low level impulse

-1.0 V ... +1.0 V

Input impedance

> 10 k

Max. input current

5 mA

Min. pulse width

400 µs

Rate of measurement

1 measurement/sec

Resolution

1 Hz

Measurement range

0 ... 51 l/min

3.2 Electrical data

Supply voltage

Voltage level

24 V DC ± 10 %

Ripple

< 5 %

Current comsumption

< 30 mA (without valve current)

< 300 mA (with valve current)

The volumetric flow of the
tanked petrol is measured by
the piston meter, is converted
into a frequency-proportional
pulsed signal by the petrol pump
computer and is sent to the
frequency input of the controller
(Figure 3).
In the controller, this pulsed sig-
nal will be processed to obtain
the actual value of the volumetric
flow of the petrol.

Input 1

VDD

to the
CPU

Figure 3.
Frequency input of
the controller