4.3

List of the objects for Digital Batch Controller Type 1115

20

UINT16

Mask process values

21

UINT8

Hardware unit

22

FLP

Actual volume 1

23

FLP

Actual volume 2

24

FLP

Actual volume 1 + 2

25

FLP

Residual volume 1

26

FLP

Residual volume 2

27

FLP

Residual volume 1 + 2

28

FLP

Required volume 1

29

FLP

Required volume 2

30

FLP

Required volume 1 + 2

31

FLP

Exact limit 1

32

FLP

Exact limit 2

33

FLP

Throughput 1

34

FLP

Throughput 2

35

FLP

Throughput 1 + 2

36

FLP

Total volume 1

37

FLP

Total volume 2

38

FLP

Total volume 1+2

39

UINT8

Condition 1

0:

Channel turned off

1:

Filling procedure stopped

2:

Approximate proportioning

3:

Exact proportioning

4:

Runoff

5:

Filling procedure completed

6:

Channel placed back

40

UINT8

Condition 2

0:

Channel turned off

1:

Filling procedure stopped

2:

Approximate proportioning

3:

Exact proportioning

4:

Runoff

5:

Filling procedure completed

6:

Channel placed back

41

UINT8

Total condition

0:

Process at standstill

1:

Process in progress

2:

Process will be placed back

3:

Manual proportioning

42

UINT8

Starting time in hours

43

UINT8

Starting time in minutes

44

UINT8

Starting time in seconds

45

UIN16

Remaining proportionings

Advertising