The controller is fitted with a steerable M12 fixed connector:
Unfasten counternut. Turn the fixed connector to the right position, but by max. 360° to avoid
twisting of the cables inside the housing. Fasten counternut using the appropriate tool while
maintening the fixed connector in the right position.

operating safety
When the voltage at the relay terminals is higher than 24 V and the cable
plugs are not correctly plugged-in and tightened, there is a risk to elec-
trocute yourself.
Always check all the cable plugs before powering the device to ensure
the good operating of the device.

4.3. Version with relay and frequency outputs

Wiring of fixed connector m12

(12-30 Vdc power supply and frequency output)

Common

Not connected

Normally Closed

Normally Open

Frequency

Not connected

(*)

(*) Functional earth

frequency output

Freq.

1

3

2

4

5

3

1

2

0 VDC

V+

(12-30 VDC)

relay output wiring of

en 175301-803 fixed connector